Esoteric DV-30s Service Manual Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 46
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
Manual No. 405/0101 ANNUAL SERVICE 28
ANNUAL SERVICE - PAGE 28
7.5 REPLACE THE CASE
Refer to Fig. 30, if necessary.
1. If a programmer is used, ensure that the test switch on the top of the control box is set to O (off).
2. Carefully slide the bottom panel assembly into position (the bottom panel goes above the returns on the case side
panels), clip the neon, see Fig. 31, into its holder on the back of the control panel as the bottom panel is slid into
position. With the control panel cover open, secure the control panel to the side panels with the two countersunk hd.
screws previously removed.
Note: If a programmer is fitted it will be necessary to connect the programmer wiring harness to the rear of the
programmer as the bottom panel assembly is slid into position.
3. Place the outer case front panel in position over the four fixings (two on each side panel) and push the panel back to
engage the fixing pins into the front panel.
Note: Types of screws used:
a. Small machine screws (M4)................Pilot burner (6 lg.) and fan to flue turret (10 lg.).
b. Small c'sk machine screws (M4).........Control panel to side panels.
c. Large machine screws (M5)................Fan assembly, flue hood/blanking plates (80 model) and burner.
d. Extended machine screws (M5)..........Flue hood (rear on all except 80 model).
e. Self tapping screws (No.8)..................Combustion chamber front, flue hood distribution plate, flue
hood/blanking plates (front and sides on all except 80 model)